Detailed description   
2.12 Block descriptions 
  Power Line Basic PLC Program (P3) 
2-206  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
More information about motor speed adjustment can be found in: 
References: 
/FB/ Description of Functions, Basic Machine; Spindles (S1); 
Section: Configurable Gear Adjustments 
/FB/ Description of Functions, Basic Machine; Velocities, Setpoint/Actual Value Systems, 
Closed-Loop Control (G2) 
Error message 
If the parameter "SpindleIFNo" is not in the permissible range, the PLC is stopped with 
output of alarm message number 401702. 
Special features 
When parameterizing "TimeVal" with the value 0, a default value of 100 ms is used. With a 
value of less than 50 ms, the minimum setting of 50 ms is applied.  
The block must be called unconditionally. 
 
 
Note 
Changeover does not occur if the spindle is in an axis mode, such as M70, SPOS. 
 
Supplementary conditions 
Star/delta changeover on digital main spindle drives initiates a process, which contains 
closed-loop control sequences. Since the closed-loop control system supports automatic 
star/delta changeover, certain restrictions should be noted: 
•  Due to the automatic deactivation of the pulses on the drive, IS "Current controller active" 
(DB31, ... DBX61.7) and "Speed controller active" (DB31, ... DBX61.6) are deactivated 
simultaneously to IS "Pulses enabled" (DB31, ... DBX93.7). 
•  If a changeover from star to delta takes place while the spindle is rotating and the spindle 
position controller is switched on, IS "Position controller active" (DB31, ... DBX61.5), this 
triggers alarm 25050 "Contour monitoring". 
•  Once the star/delta changeover has been initiated with FC17, the changeover of the 
star/delta contactor cannot be delayed by the user. The user can implement this signal 
interaction with PLC logic.