Detailed description 
  2.12 Block descriptions 
Power Line Basic PLC Program (P3) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-211 
The oscillation speed is taken from machine data: 
MD35400 SPIND_OSCILL_DES_VELO  
 
MD35010 
GEAR_STEP_CHANGE_
ENABLE = 0 
Function  MD35010: 
GEAR_STEP_CHA
NGE_ENABLE = 1 
Function 
Pos = 0  Oscillation  Pos = 0   
Pos = 1  Oscillation  Pos = 1  Oscillation with gear stage change 
M41 
Pos = 2  Oscillation  Pos = 2  Oscillation with gear stage change 
M42 
Pos = 3  Oscillation  Pos = 3  Oscillation with gear stage change 
M43 
Pos = 4  Oscillation  Pos = 4  Oscillation with gear stage change 
M44 
Pos = 5  Oscillation  Pos = 5  Oscillation with gear stage change 
M45 
 
4. Traverse indexing axis: 
The following signals are relevant: 
 
Start:  Initiation signal 
Funct:  "4" = Indexing axis 
 
 
 
Note 
With 
Funct: "4" = Indexing axis 
The modulo conversion can be compared with approaching the indexing position via 
POS[AX] = CIC (value) in the part program. 
 
 
 
Mode:  Positioning mode 0, 1, 2, 3, 4 
AxisNo:  Number of machine axis 
Pos:   Indexing position 
FRate:  Positioning speed; if FRate = 0, 
the value is taken from machine data POS_AX_VELO 
(unit as set in machine data). 
InPos:  Is set to "1" when position is reached with "Exact stop fine". 
Error:  With positioning error = "1" 
State:  Error code