Detailed Description   
2.3 Starting up hardware configuration of PLC CPUs 
  PLC Basic Program Solution Line (P3 sl) 
2-10  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
 
Fig. 2-2  DP slave properties 
In the Properties dialog box for the integrated SINAMICS drive, object codes 1 to 6 are used 
to identify axes 1 to 6. The axes are set for message frame type 106 and Safety Motion 
Monitoring as standard. This is the default setting. Message frame type 106 features the 
longest possible user data length of an NC axis. The message frame type in the NC machine 
data may not tally at all with this setting. In the context of an NC axis, message frame type 
means: 2 encoders + DSC. 
Object 7 contains the ALM via which, for example, enables have to be activated by the PLC 
user program. Object 8 contains the Dev0 (Device 0).  
Axis expansions with the NX10 and NX15 modules are possible for NCU720 and NCU730. 
You will find NX10 and NX15 in the PROFIBUS DP\SINAMICS module catalog. 
You will find the clock settings for the drives in the dialog box under the tab.