Detailed Description   
2.5 Linking PLC CPUs to 840D 
  PLC Basic Program Solution Line (P3 sl) 
2-20  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Exchange with the operator panel front 
Data exchange with the operator panel (HMI, OP) usually takes place via the internal 
software-based C bus. Alternatively, external HMI or OP systems can also be connected on 
Ethernet or the MPI bus. In the event of connection to the Ethernet bus, the integrated CP 
provides the link to the PLC. On the 840D, data exchange with the machine control panel 
(MCP) and handheld unit (HHU) is determined by the interface setup of the MCP/HHU. 
Possible connection paths include: MPI, PROFIBUS, Ethernet. 
Programming devices should be connected to the Ethernet bus via the internal CP or via the 
MPI (Multi-Point-Interface) directly to the PLC. 
 
 