The assignment between the M function with extended address and the bit to be set in the 
signal list is specified via the first and last M functions in the decoding list.  
The bit address is generated correspondingly from the first M function ("MFirstAdr") to the 
last M function ("MLastAdr") from bit 0 up to maximum bit 15 for each group. 
Each entry in the decoding lists consists of 3 parameters, each of which is assigned to a 
group. 
 
Assignment of groups 
Group  Extended  
M address 
First M address in group  Last M address in group 
1  MSigGrp[1].MExtAdr  MSigGrp[1].MFirstAdr  MSigGrp[1].MLastAdr 
2  MSigGrp[2].MExtAdr  MSigGrp[2].MFirstAdr  MSigGrp[2].MLastAdr 
...  ...  ...  ... 
16  MSigGrp[16].MExtAdr  MSigGrp[16].MFirstAdr  MSigGrp[16].MLastAdr 
 
 
Type and value range for signals 
Signal  Type  Value range  Remarks 
MExtAdr  Int  0 to 99  Extended M address 
MFirstAdr  DInt  0 to 99,999,999  First M address in group 
MLastAdr  Dint  0 to 99,999,999  Last M address in group 
Signal list 
Data block DB 76 is set up when the function is activated. 
A bit is set in the appropriate group in DB 76 for an M signal decoded in the list. 
At the same time, a read-in disable is set in the channel in which the M function has been 
output. 
Example 
Three groups of M commands are to be decoded in the following example: 
•  · M2 = 1 to M2 = 5 
•  · M3 = 12 to M3 = 23 
•  · M40 = 55