Detailed Description 
  2.7 Structure and functions of the basic program 
PLC Basic Program Solution Line (P3 sl) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-51 
'%
8VHUPDFKLQH
GDWDW\SH,17
1RRI8',QW
1RRI8'+H[
1RRI8'5HDO
8VHUPDFKLQH
GDWDW\SH%<7(
8VHUPDFKLQH
GDWDW\SH5($/
 
Fig. 2-15  DB 20 
 
 
Note 
If the number of PLC machine data used is increased later, then DB20 must be deleted 
beforehand. To prevent such extensions in use having any effect on the existing user 
program, the data in DB20 should be accessed in symbolic form wherever possible, e.g., by 
means of a structure definition in the UDT. 
 
 
 
Interrupts 
400120  Delete DB 20 in PLC and restart 
Explanation  DB length is not the same as the required DB length 
Reaction  Interrupt display and PLC STOP 
Remedy  Delete DB 20 followed by Reset 
Continuation  After cold restart