Detailed Description 
  2.10 Memory requirements of basic PLC program for 810D, 840D 
PLC Basic Program Solution Line (P3 sl) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-67 
Basic program options 
  Machine control panel 
FC 19  Transfer of MCP signals, 
M variant 
Must be loaded when M variant of MCP is 
installed 
  1538 
FC 25  Transfer of MCP signals, 
T variant 
Must be loaded when T variant of MCP is 
installed 
  1328 
FC 24  Transfer of MCP signals,  
slim variant 
Must be loaded when slim variant of MCP is 
installed 
  1522 
FC 26  Transfer of MCP signals, 
HPU variant 
Must be loaded for HPUs    1216 
FC 14  MPI/OPI transfer  Must be loaded if MCPNum > 0    802 
  Handheld unit 
FC 13  Display control HHU  Can be loaded for handheld units    1032 
  Error/operating messages 
FC 10  Acquisition FM/BM  Load when FM/BM is used    1354 
  ASUB 
FC9  ASUB start  Load when PLC ASUBs are used    518 
 
 
Basic program options 
  Star/delta changeover 
FC 17  Star/delta switchover of 
MSD 
Load for star/delta switchover    492 
  Spindle control 
FC 18  Spindle control  Load for spindle control from PLC    882 
  PLC/NC communication 
FB 2  Read NC variable  Load for Read NC variable    350 
DB n1)  Read NC variable  One instance DB per FB 2 call    270 each 
FB 3  Write NC variable  Load for Write NC variable    350 
DB m1)  Write NC variable  One instance DB per FB3 call    270 each 
FB 4  PI services  Load for PI services    296 
DB o1)  PI services  One instance DB per FB4 call    130 each 
DB 16  PI services description  Load for PI services    618 
FB5  Read GUD variables  Load for PI services    472 
DB p  Read GUD variables  One instance DB per FB5 call    166 each 
FB 6  General  
communication 
Load for Read/write NC variables and PI 
services 
  5512 
DB 15  General  
communication 
Instance DB for FB 6    280 
FB7  PI services 2  Load for PI services    300 
DB o  PI services 2  One instance DB per FB4 call: every    144 
FC 21  Transfer  Load with dual-port RAM, ...    1074 
 m:n