EasyManua.ls Logo

Siemens SINUMERIK 840DE SL - Page 1282

Siemens SINUMERIK 840DE SL
2050 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Detailed Description
2.12 Block descriptions
PLC Basic Program Solution Line (P3 sl)
2-88 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Signal Type Type Value range Remarks
MCP1Cycl
MCP2Cycl
I S5time Recommendation:
200 ms
Time reference for cyclic updating
of signals to machine control panel
MCPMPI I Bool 1: All machine control panels
connected to the MPI bus (without
GD parameterization)
MCP1Stop
MCP2Stop
I Bool 0: Start transfer of machine control
panel signals
1: Stop transfer of machine control
panel signals
DP slave: Slave deactivated
MCP1NotSend
MCP2NotSend
I Bool 0: Send and receive operation
activated
1: Receive machine control panel
signals only
MCPSDB210 I Bool 0: No SDB 210 for MCP
1: Activate timeout monitors on
SDB 210 for MCP
MCPCopyDB77 I Bool 1: Copy between DB 77 and MCP
pointers on DB 7
Can only be used with standard
SDB 210 configuration on DB 77.
MCPBusType I Byte 0: MPI or MCP
b#16#33: Profibusb
#16#55: Ethernet
Mixed operation possible, see
MCP/HHU configuration
HHU I Int HHU interface
0: No HHU
1: HHU on MPI with SDB 210
configuration
5: HHU on Ethernet
BHGIn I Pointer I0.0 to I124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address
PLC receive data
from HHU
BHGOut I Pointer Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address
PLC transmit data
to HHU
BHGStatSend I Pointer Q0.0 to Q124.0,
F0.0 to F252.0 or
DBn DBX0.0 to
DBXm.0
Start address for status double
word for transmitting data to HHU:
DW#16#08000000: Timeout,
otherwise 0

Table of Contents

Other manuals for Siemens SINUMERIK 840DE SL

Related product manuals