Multiple calls of FC 25 are permitted in a single PLC cycle. In this case, the first call in the 
cycle activates the LED displays. Furthermore, all actions of the parameterized block are 
carried out in the first call. In the following calls, only a reduced level of processing of the 
channel and mode group interface takes place. The geometry axes are supplied with 
directional data only in the first block call in the cycle.  
Single-block processing can be selected/deselected only in the first cycle. 
The second machine control panel can be processed if parameter ModeGroupNo has been 
increased by B#16#10. When parameterizing, the HHU number is contained in the lower 
nibble (lower 4 bits).  
BAGNo = 0 or B#16#10 means that the mode group signals are not processed.  
ChanNo = 0 means that the channel signals are not processed. 
Flexible axis configuration 
It is possible to be flexible in the assignment of axis selections or direction keys for machine 
axis numbers.  
Better support is now provided by the MCP blocks for the use of two MCPs, which are to run 
in parallel, in particular for an application using two channels and two mode groups. The 
block call for the 2nd machine control panel in the OB1 cycle must come after the call for the 
1st MCP. Note that the axis-numbers are also specified in the parameterized mode group 
number of the MCP block in the axis tables of the relevant MCP. 
To afford this flexibility, tables for axis numbers are stored in DB 10. For the first machine 
control panel (MCP), the table starts at byte 8 (symbolic name: MCP1AxisTbl[1..22]) and at 
byte 32 for the second MCP (symbolic name: MCP2AxisTbl[1..22]) for the second MCP. The 
machine axis numbers must be entered byte by byte here.  
It is permissible to enter a value of 0 in the axis table. Checks are not made to find 
impermissible axis numbers, meaning that false entries can lead to a PLC Stop.  
For FC 19, the maximum possible number of axis selections can also be restricted. This limit 
is set for the appropriate MCP in DB10.DBW30 (symbolic name: MCP1MaxAxis) or 
DB10.DBW54 (symbolic name: MCP2MaxAxis). The default setting is 0, corresponding to 
the maximum number of configured axes. The axis numbers and the limit can also be 
adapted dynamically. Afterwards, a new axis must be selected on FC 19.  
Axis numbers may not be switched over while the axes are traversing the relevant direction 
keys.  
The compatibility mode is preset with axis numbers 1 to 9 for both MCPs and restricted to 
the configured number of axes. 
Declaration of the function 
 
FUNCTION FC 25: void   
// NAME:  MCP_IFT 
VAR_INPUT  
  BAGNo :  BYTE ; 
 ChanNo:  BYTE ; 
 SpindleIFNo:  BYTE ; 
END_VAR  
VAR_OUTPUT  
  FeedHold :  BOOL ;