Detailed Description   
2.12 Block descriptions 
  PLC Basic Program Solution Line (P3 sl) 
2-224  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
 
 
Note 
The spindle-specific M functions below are not decoded: M3, M4, M5, and M70. 
 
 
 
Addresses in DB21, ...  Variable  Type  Comment 
DBX 194.0 ... 7  M_Fkt_M0 ... M7  Bool  M signals M0 ... M7 
DBX 195.0 ... 7  M_Fkt_M8 ... M15  Bool  M signals M8 ... M15 
DBX 196.0 ... 7  M_Fkt_M16 ... M23  Bool  M signals M16 ... M23 
DBX 197.0 ... 7  M_Fkt_M24 ... M31  Bool  M signals M24 ... M31 
DBX 198.0 ... 7  M_Fkt_M32 ... M39  Bool  M signals M32 ... M39 
DBX 199.0 ... 7  M_Fkt_M40 ... M47  Bool  M signals M40 ... M47 
DBX 200.0 ... 7  M_Fkt_M48 ... M55  Bool  M signals M48 ... M55 
DBX 201.0 ... 7  M_Fkt_M56 ... M63  Bool  M signals M56 ... M63 
DBX 202.0 ... 7  M_Fkt_M64 ... M71  Bool  M signals M64 ... M71 
DBX 203.0 ... 7  M_Fkt_M72 ... M79  Bool  M signals M72 ... M79 
DBX 204.0 ... 7  M_Fkt_M80 ... M87  Bool  M signals M80 ... M87 
DBX 205.0 ... 7  M_Fkt_M88 ... M95  Bool  M signals M88 ... M95 
DBX 206.0 ... 3  M_Fkt_M96 ... M99  Bool  M signals M96 ... M99 
 
 
 
Note 
The M02/M30 auxiliary function output to the PLC does not state that the part program has 
been terminated. In order to securely identify the end of a part program in the channel, 
DB21, ... DBX33.5 (M02/M30 active) 
must be evaluated. The channel status must be RESET. The auxiliary function output could 
arise from an asynchronous subroutine (ASUB) or a synchronized action and has nothing to 
do with the real end of the parts program in this case.