2.4 Referencing with incremental measurement systems
Reference Point Approach (R1)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-9
Case 2: The machine axis is positioned on the reference cam
The machine axis remains at its starting position.
Phase 1 now complete. Reference point approach is continued with Phase 2.
Case 3: The machine axis has no reference cam
Machine axes without reference point cams remain at their starting position.
These include, for example:
Machine axes that only have one zero mark along their entire traversing range
Rotary axes that only have one zero mark per revolution
Zero must be entered in the following machine data for machine axes without a reference
point cam:
MD34000 $MA_REFP_CAM_IS_ACTIVE (axis with reference cam) = 0
Phase 1 is now complete. Reference point approach is continued with Phase 2.
Phase 1: Features
Feed override active.
Feed stop (channelspecific and axisspecific) is active.
NC-STOP and NC-START are active.
If in Phase 1 the machine axis does not reach the reference cam:
DB31, ... DBX12.7 (deceleration of reference point approach) = 1
within the assigned distance:
MD34030 $MA_REFP_MAX_CAM_DIST (maximum distance to the reference cam),
the machine axis is stopped.

Table of Contents