Detailed Description   
2.2 Feedrate FA for positioning axes 
  Feeds (V1) 
2-22  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Parameter: Feed value 
•  Value range 
0.001...999,999.999 mm/min, degrees/min or 0.001, ...39 999,9999 inch/min 
For more information about the value range of the axial feedrate see: 
References: 
/PA/ Programming Guide, Fundamentals" 
/FB/ Description of Functions, Basic Machine; Velocities, Setpoint/Actual-Value Systems, 
Closed-Loop Control (G2) 
•  NC/PLC interface (channel-specific) 
The feedrate is output at the channel-specific NC/PLC interface: 
DB21, ... DBB158 - DBB193 
For a description of the channel-specific NC/PLC interface signals (modification signal, 
machine axis number of positioning axis, etc.) see: 
References: 
/FB/Description of Functions, Basic Machine; Various Interface Signals and Functions 
(A2) 
•  NC/PLC interface (axis-specific) 
The feed value is output at the axis-specific NC/PLC interface: 
DB31, ... DBB78 - DBB81 
 
 
 
Note 
Maximum axis velocity  
The maximum axis velocity is not exceeded: 
MD32000 $MA_MAX_AX_VELO (maximum axis velocity) 
F function output to the NC/PLC interface 
Output of the F functions to the NC/PLC interface is not recommended. Activating the 
output of F functions to the NC/PLC interface can cause a drop in velocity in continuous-
path mode. The output of F functions to the NC/PLC interface can be suppressed: 
MD22240 $MC_AUXFU_F_SYNC_TYPE (output time of the F functions) 
For a detailed description please refer to: 
References: 
/FB/ Description of Functions - Basic Machine, Auxiliary Functions (H2) 
 
RESET response 
After end of program or NC-RESET, the feedrate value takes effect depending on machine 
data: 
MD22410 $MC_F_VALUES_ACTIVE_AFTER_RESET = <value> 
 
Value  Meaning 
0  After NC RESET the default values are effective. 
1  After NC RESET the last FA values to be programmed are effective.