Detailed Description 
  2.5 NC block compressor COMPON, COMPCURV, -CAD 
Continuous-Path Mode, Exact Stop, LookAhead (B1) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-43 
If not, the value can be increased to 0.02, for example: 
 
MD33100 COMPRESS_POS_TOL[AX1] = 0.02  
MD33100 COMPRESS_POS_TOL[AX2] = 0.02 
MD33100 COMPRESS_POS_TOL[AX3] = 0.02 
NewConfig 
Activating the MD values 
The new values are activated after the NewConfig command. 
The rounding function G642 and jerk limitation SOFT can be used to achieve further 
improvements in surface quality. These commands must be entered at the start of the 
program:  
COMPCAD SOFT G642 
COMPOF terminates the compressor function. 
All blocks are compressed for which a simple syntax is sufficient: 
N... G1X... Y... Z... F... 
where "..." is a number and X, Y, Z are axis names.  
Blocks with e.g., extended addresses such as C=100 or A=AC(100) or blocks with auxiliary 
functions are also compressed.