Detailed Description 
  2.1 Velocities, traversing ranges, accuracies 
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-9 
,QSXWRXWSXWXQLWVIRUPDFKLQH
DQGVHWWLQJGDWD
&RQYHUVLRQRILQWHUQDOXQLWV
,QWHUQDOXQLWV
8VHUGHILQHG
0'6&$/,1*B)$&7256B86(5B'()>Q@
0'6&$/,1*B)$&7256B86(5B'()B0$6.
'RWKH
LQSXWRXWSXWXQLWVFRUUHV
SRQGWRWKHVWDQGDUGEDVLF
V\VWHP"
LQFKRUPHWULF
1R
<HV
 
 
The following applies: 
Selected input/output unit = MD10230 * internal unit 
The selected input/output unit is input into machine data: 
MD10230 $MN_SCALING_FACTORS_USER_DEF[n], 
expressed in internal units of 1 mm, 1 degree or 1 s.  
Example 1: 
Machine data input/output of the linear velocities is to be in m/min instead of mm/min (initial 
state).  
(The internal unit is mm/s) 
 
⇒  The scaling factor for the linear velocities is to differ from the standard setting. In this case, bit 
number 2 must be set in machine data: 
MD10220 $MN_SCALING_USER_DEF_MASK. 
  ⇒  MD10220 $MN_SCALING_USER_DEF_MASK = 'H4'; (bit no. 2 as hex value)