Detailed Description 
  2.3 Setpoint/actual-value system 
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2) 
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
2-31 
Measurement channel no. 6 should be assigned to machine axis "X1": 
X416 as direct measuring system. 
The logical number of the drive is set automatically to 4. 
;
; ;
;;
;
0''5,9(B/2*,*B15
0'180B(1&6
0'&75/287B15 
0'&75/287B02'8/(B15 
0'&75/287B7<3( 
0''5,9(B02'8/(B7<3( 
0'(1&B7<3(
0'(1&B02'8/(B15
0'(1&B,1387B15
'
0*
'
7DEOH
6SLQGOH
/LQHDUVFDOH
3RZHU
$[LVH[SDQVLRQ
LQWHUIDFH
$FWXDOYDOXH
FRQQHFWRU
3RZHUXQLW
H[WHUQDO
 
Fig. 2-3  Example of setpoint/actual-value routing with axis expansion interface 
 
Actual-value assignment  Machine data parameterization for 810D 
1st axis actual value from motor 
encoder 
(X414)  MD30220 $MA_ENC_MODULE_NR[0]  
MD30230 $MA_ENC_INPUT_NR[0]  
= 4 
= 1 
2nd axis actual value from linear 
scale 
(X416)  MD30220 $MA_ENC_MODULE_NR[1]  
MD30230 $MA_ENC_INPUT_NR[1]  
= 3 
= 1 
Number of encoders:    MD30200 $MA_NUM_ENCS   = 2 
Actual-value acquisition modes  1:  MD30240 $MA_ENC_TYPE[0]   = 1 
  2:  MD30240 $MA_ENC_TYPE[1]   = 1