Detailed Description
2.4 Closed-loop control
Velocities, Setpoint/Actual-Value Systems, Closed-Loop Control (G2)
Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
2-51
The type of fine interpolation can be defined via machine data:
MD33000 $MA_FIPO_TYPE (fine interpolation type).
A differential FIPO not only performs cycle matching but also calculates a mean value
(smoothing) from an IPO cycle.
The cubic FIPO, type 3, supplies the best contour accuracy in addition to the cycle
adaptation.
K
v
factor
To ensure that only low contour deviations occur in continuous-path mode,
a high servo gain factor (K
v
):
MD32200 $MA_POSCTRL_GAIN[n]
is required.
However, if the servo gain factor (K
v
) is too high, instability, overshoot and possibly
impermissibly high loads on the machine will result.
The maximum permissible servo gain factor (K
v
) depends on the following:
Design and dynamics of the drive
(rise time, acceleration and braking capacity)
Machine quality
(elasticity, oscillation damping)
Position-control cycle
The servo gain factor (K
v
) is defined as follows:
9HORFLW\
)ROORZLQJHUURU
>PPLQ@
.9
>PP@
[m/min]/[mm]: Unit of servo gain factor (K
V
) according to VDI standard