Detailed Description   
2.6 Block search Type 5 SERUPRO 
  Mode Group, Channel, Program Operation, Reset Response (K1) 
2-40  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
4.  The part program command WAITM/WAITE/WAITMC will wait for the partner channels 
involved. 
This waiting occurs if the partner channels are: 
– In SERUPRO mode 
– In Program test more or are actually running 
5.  Selection of program test and dry run feedrate is rejected with corresponding 
Alarm 16935. 
6.  The NC stops at the beginning of the target block, deselects "Program test" internally, 
and displays the Stop condition "Search target found" in its block display. 
7.  As required, the user can start an ASUB that is traversed really. This ASUB is referred to 
below as the SERUPRO-ASUB. 
8.  The user presses Start: 
The spindles are started. Then, the path axes start a REPOS operation that guides them 
to the block starting point of the target block. 
The REPOS operation is implemented by a system ASUB and can be expanded using 
the "Editable ASUB" function. 
SERUPRO operation 
The sequence of operations in items 2. to 6. corresponds to one SERUPRO operation.  
SERUPRO ASUP 
An ASUB that can be called optionally when the target block is reached. It is actually 
executed.  
SERUPRO approach 
Approach to the starting point of the target block during a block search in SERUPRO test 
mode.  
Boundary conditions for block search SERUPRO 
The SERUPRO function may only be activated in "AUTOMATIC" mode and may only be 
aborted in program status (channel status RESET). 
If in normal mode only the PLC starts commonly several channels, then this can be 
simulated by SERUPRO in each channel. 
If machine data setting: 
MD10708 $MN_SERUPRO_MASK Bit 1 = 0 
Alarm 16942: "Channel %1 Start program command action %2<ALNX> not possible" 
aborts the simulation if part program command START is used.  
Machine data: 
MD10707 $MN_SERUPRO_TEST_MASK 
allows program testing to be deactivated in the stopped state without the SERUPRO 
operation being affected. The default setting allows program testing to be deactivated only in 
the RESET state.