Detailed Description
2.7 Program operation mode
Mode Group, Channel, Program Operation, Reset Response (K1)
2-112 Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0
Handling
Replacement of system routine
MD 11610 MN_ASUB_EDITABLE controls which of the system routines are to be replaced
by user-defined routines.
Value Meaning
0 The user-defined routine stored in _N_ASUP_SPF in directory _N_CUS_DIR
is not activated for either RET or REPOS.
1 The user-defined routine is activated for RET,
the routine provided in the system is activated for REPOS.
2 The user-defined routine is activated for REPOS,
the routine provided in the system is activated for RET.
1
2
0
User
RET
User
REPOS
Value stored in MD 11610
_N_ASUP_SPF
System
ASUB
RET
System
ASUB
REPOS
System
ASUB
REPOS
System
ASUB
RET
NCK system SW
User SW
ASUP_EDITABLE
Fig. 2-14 Replacing system ASUBs with user routines