Detailed Description   
2.9 Program control 
  Mode Group, Channel, Program Operation, Reset Response (K1) 
2-134  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
Subroutine_N_ROUGHING_SPF  
(stored in HMI memory under workpieces->WP1) 
 
N010 PROC ROUGHING     
N020 G1 F1000     
N030 X= ... Y= ... Z= ...     
N040 .....     
....   
....   
N999999 M17     
Windows path name 
Program to be reloaded is stored on network drive or ATA card 
•  EXTCALL Windows path name 
Call for network drive (HMI Embedded or HMI Advanced) e.g., 
EXTCALL \\R4711\Workpieces\Contour.1.spf 
Call for ATA card (HMI Embedded) e.g., 
EXTCALL C:\Workpieces\Contour.2.spf 
 
 
 
Note 
An absolute path must always be specified in HMI Embedded. 
For further explanations about operation under HMI Embedded/Advanced, refer to: 
References:  
/BEM/, HMI Embedded, "Execution from network", "Execution from ATA card" and 
"EXTCALL" 
/BAD/, HMI Advanced, access to external network drive/computer 
 
Power On, RESET 
External subroutine calls are aborted and the respective FIFO (reload) buffer erased by a 
RESET or POWER ON. 
A program selected for "Process from external" remains selected for "Process from external" 
after a Reset. A POWER ON deletes the selection. Default program MPF0 is selected 
instead.