Detailed Description   
2.1 Motion monitoring functions 
  Axis Monitoring, Protection Zones (A3) 
2-8  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
 
Note 
The NC detects whether an axis is clamped based on the "servo enable" state of the axis: 
DB31, ... DBX2.2 = 0 (servo enable): no servo enable ⇒ axis is clamped 
DB31, ... DBX2.2 = 1 (servo enable): servo enable ⇒ axis is not clamped 
 
Prerequisites for the PLC user program 
•  The axis is always removed from the clamp when a travel command is pending. 
•  The following is always valid for the axis: 
DB31, ... DBX2.2 = 0 (servo enable): Axis is clamped 
DB31, ... DBX2.2 = 1 (servo enable): Axis is not clamped 
The following image shows an example of the interface signals and states upon releasing of 
the axis clamp. The part program blocks N310 and N410 refer to the schematic example 
under certain boundary conditions. 
W>PV@
5HOHDVHD[LVFODPSIRU
0'6723B21B&/$03,1*>@ +
&ODPSD[LV
)HHGVWRS
0RWLRQFRPPDQG
&RQWUROOHUHQDEOH
3DWKYHORFLW\
1
*=
1
*$7XUQURWDU\WDEOHGHJUHHV
$[LVFODPSLQJSUHVVXUH
 
Fig. 2-3  Example 1: Interface signals and states