Detailed description   
2.5 Linking PLC CPUs to 810D, 840D 
  Power Line Basic PLC Program (P3) 
2-28  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
All values must be converted to decimal values and lined up in order of alarm or message 
number: 
 
Event ID:  46
 hex
  =  70 
dec
 
Supplementary 
information 1 
  00 
hex
  =    00 
dec
 
Supplementary 
information 2 
    20 
hex
  =    32 
dec
 
Alarm number (OM) 
1)
 = 70 00 32 
1) controlled by DB2.DBX184.0   
OM = operational message   
 
This signifies the event with Event ID 16# B046 and the indicated supplementary information 
"Message 700032 deleted". 
Notes 
•  The meaning of the message number is specified by the machine manufacturer. 
•  Events with Event ID 16# xx28 or 16# xx29 are generated from the basic program. 
•  The messages stored in the diagnostic buffer can be read out on the MMC with the 
associated message texts.