Detailed description   
2.6 Interface structure 
  Power Line Basic PLC Program (P3) 
2-42  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
MCP interface in the PLC 
The signals from the machine control panel are routed via the I/O area by default. A 
distinction is made between NC and machinespecific signals. NCspecific key signals are 
normally distributed by FC 19 to the various mode group, NCK, axis and spindlespecific 
interfaces. The reverse applies to the status signals, which are routed to the machine control 
panel interface. 
 
 
Note 
FC 19 must be called in the PLC user program. 
 
Customized keys, which can be used to trigger a wide range of machine functions, must be 
evaluated directly by the user program. The user program also routes the status signals to 
the output area for the LEDs. 
)&