Detailed description   
2.7 Structure and functions of the basic program 
  Power Line Basic PLC Program (P3) 
2-70  Function Manual, 08/2005 Edition, 6FC5397-0BP10-0BA0 
03,'3
'3
++8
1&
23,
0&3
0&3
'
3
5
352),
%86IRU
0&
&2
LQW
 
 
 
Relevant parameters (FB1) 
MCP  HHU 
MCPNum = 1 or 2 (number of MCPs)  HHU = 2 (via COM module) 
MCP1In  MCP2In  BHGIn 
MCP1Out  MCP2Out  BHGOut 
MCP1StatSend (n.r.)  MCP2StatSend (n.r.)  BHGStatSend 
MCP1StatRec (n.r.)  MCP2StatRec (n.r.)  BHGStatRec 
MCP1BusAdr  MCP2BusAdr  BHGInLen 
MCP1Timeout (n.r.)  MCP2Timeout (n.r.)  BHGOutLen 
MCP1Cycl (n.r.)  MCP2Cycl (n.r.)  BHGTimeout 
MCPMPI = FALSE    BHGCycl 
MCP1Stop (n.r.)  MCP2Stop (n.r.)  BHGRecGDNo 
MCPBusType = 3    BHGRecGBZNo 
    BHGRecObjNo 
    BHGSendGDNo 
    BHGSendGBZNo 
    BHGSendObjNo 
    BHGMPI = FALSE 
    BHGStop 
MCP failure switches the PLC to the STOP state. If this is undesirable, OB 82, OB 86 can be 
used to avoid a stop. The MCP (as PROFIBUS slave) can also be switched on and off via 
SFC12.  
In the event of a failure, alarm messages are not generated by the basic program.  
M to N is not possible with the MCP variant.