No. Parameter
mask
Parameter
internal
Data type Meaning
23 <_DMODE> INT Display mode
UNITS: Machining plane G17/G18/G19
0 = Compatibility, the plane effective before
the cycle call remains active
1 = G17 (only active in the cycle)
2 = G18 (only active in the cycle)
3 = G19 (only active in the cycle)
TENS: Reserved
HUNDREDS: Reserved
THOUSANDS: Compatibility mode (for recompilation screen
form only),
if MD 52216 bit0 = 1
1)
0 = Technology parameters are displayed
(compatibility): TECHNO parameters ef‐
fective
1 = Technology parameters are not dis‐
played: Technology active "as before cy‐
cle call"
TEN THOUSANDS: Technology scaling in cycle screen forms
(Page 1153)
0 = Input: Complete
1 = Input: Simple
Work preparation
3.25 Programming cycles externally
NC programming
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0 1073