Note
GETVARAP can be used, for example, to implement a checking program that checks the
access rights expected by the application.
Read limit values
Syntax:
<Status>=GETVARLIM(<name>,<limit value>,<result>)
Meaning:
<Status>: Function status
Data type: INT
Range of val‐
ues:
1 OK
-1 No limit value defined
(for variables of type AXIS, STRING, FRAME)
-2 The specified variable name has not been assigned to a
system parameter or a user variable.
-3 Incorrect value for the parameter <limit value>
GETVARLIM: Reading of the lower/upper limit value of a system/user variable
<name>: Name of the system/user variables
Data type: STRING
<limit
value>:
specifies which limit value should be read out
Data type: CHAR
Range of val‐
ues:
"L" Lower limit value
"U"
:
Upper limit value
<result>: Return of the limit value
Data type: VAR REAL
Example:
Program code Comment
DEF INT state=0
DEF REAL result=0
state=GETVARLIM("$MA_MAX_AX_VELO","L",result) ; Determine the lower limit val-
ue for MD32000 $MA_MAX_AX_VELO.
IF (result < 0) GOTOF error
Read dimension value
Syntax:
<Result>=GETVARDIM(<Name>,<Index>)
Work preparation
3.1 Flexible NC programming
NC programming
Programming Manual, 12/2019, 6FC5398-2EP40-0BA0 429

Table of Contents

Other manuals for Siemens SINUMERIK ONE MCP 2400.4c

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINUMERIK ONE MCP 2400.4c and is the answer not in the manual?

Siemens SINUMERIK ONE MCP 2400.4c Specifications

General IconGeneral
BrandSiemens
ModelSINUMERIK ONE MCP 2400.4c
CategoryControl Systems
LanguageEnglish

Related product manuals