2-24
1010ENFM-3B
Section 2
2. A typical menu screen will appear as shown below and indicate the current ALC (e.g., 50).
This ALC number indicates the current receive signal strength and can be used for further
diagnostic purposes.
3. To exit Force Transmit, press the <Left Arrow> and a Detection Fault prompt will appear (see
above). Press the <Left Arrow> again and the meter will return to the Pick/Install Xdcr menu
and highlight the [Empty Pipe Set] menu cell.
4. To force a frequency, repeat steps 1 and 2 above, but press <Right Arrow>. The following
typical display line will appear:
Using numeric keys enter the frequency and press <ENT>.
5. If the Force Transmit diagnostic procedure is not used, the normal [Install Completed?]
function occurs as follows:
To complete the Install process after mounting the transducers press <ENT>.
Drive
=0
Transducer Model 1011 Universal
Transducer Size B3
Xdcr Mount Mode Direct
Spacing Offset Minimum
Number Index 4
Spacing Method Track 1012TP
Ltn Value (in) 0.217
Install Completed? Install
Empty Pipe Set Channel Not Setup
Zero Flow Adjust Channel Not Setup
Siemens 2 Channel [1] SITE1
ForceN fx=8 m=7 ALC=50
Pick/Install Xdcr
Transducer Model 1011 Universal
Transducer Size B3
Xdcr Mount Mode Direct
Spacing Offset Minimum
Number Index 4
Spacing Method Track 1012TP
Ltn Value (in) 0.217
Install Completed? Install
Empty Pipe Set Channel Not Setup
Zero Flow Adjust Channel Not Setup
Siemens 2 Channel [1] SITE1
Pick/Install Xdcr
Detection Fault
Press [ENT]