Measurement X should be 4,40 mm (…inch), +/- 0,03 mm
Measurement X1 should be 2,80 mm (…inch) +/- 0,03 mm
Measurement Y should be 9,50 mm (... inch) +/-0,03mm
If this is not the case, e.g. X = 4,50 and Y = 9,40 proceed as follows:
Choose 4 “Calibrations” from the main menu and press ENTER
Choose 3 “Adapters” and press ENTER
Choose 3 “E3 - Pump (cutting)” and press ENTER.
Position the pointer at the side of the parameter to be edited with the arrow keys or [ENTER] and use the
following keys to edit the parameters:
SHIFT + [arrow up]:increases the value within + 300 hundredths of a mm or hundredths of a degree (axis B)
+ 20 cent. mm X/Y1/Y2
SHIFT + [arrow down]: decreases the value within - 300 hundredths of a mm or hundredths of a degree (axis
B) - 20 cent. mm X/Y1/Y2
CLEAR = to zero the value
Esempio:
[ENTER] = in the last field to quit the window so that the query Save? appears for the edited data.
[START] = press START to begin the automatic gauging procedure.
Press [ENTER]
Digit the corrections required for axis X and axis Y.
Press [ENTER]
ATTENTION: if [STOP] is pressed the new measurements are not saved; the previous gauging values therefore
remain valid.
Press ENTER to confirm the data.
4 - Calibration
5 - Maintenance
6 - Options
1 - Clamps
2 - Cutters
3 - Adapters
Adapters
1: E1 - Mortice
2: E2 - Bit Stop Female
3: E3 - Pump (cutting)
Adapter E3
Side: Cutting:
Adjustments: B=+000
X=+00 Y1=+00 Y2=+00
Adapter E3
Side: Cutting:
Adjustments: B=+000
X=+10 Y1=-10 Y2=+00
Save
adjustment ?
No=STOP Yes=ENTER