102 Copyright Silca 2004
IDEA Operating Manual - English
Press STOP, remove the key and use a centesimal gauge to measure it
.
Fig. 127
Measurement Y should be 4,40 mm (…inch), +/- 0,03 mm
[Measurement Y1 should be 2,80 mm (…inch) +/- 0,03 mm]
Measurement X should be 9,50 mm (... inch) +/-0,03mm
If this is not the case, e.g. X = 9,40 and Y = 4,30 proceed as follows:
Choose “4 Calibrations” from the main menu and press ENTER
.
Choose 3 “Adapters” and press ENTER.
Choose 7 “E7 - Pump (reading)” and press ENTER.
Position the pointer at the side of the parameter to be edited with the arrow keys or [ENTER] and use the
following keys to edit the parameters:
SHIFT + [arrow up]:increases the value within + 300 hundredths of a mm or hundredths of a degree (axis B)
+ 20 cent. mm X/Y1/Y2
SHIFT + [arrow down]: decreases the value within - 300 hundredths of a mm or hundredths of a degree (axis
B) - 20 cent. mm X/Y1/Y2
CLEAR = to zero the value.
Copy 1 of 1
finished
More copies ?
No=STOP Yes=ENTER
4 - Calibrations
5 - Maintenance
6 - Options
1 - Clamps
2 - Cutters
3 - Adapters
4: E4 - Muel (cutting)
5: E5 - Fiam (cutting)
6: E6 - Fiam (reading)
7: E7 - Pump (reading)
Adapter E7
Side: Cutting:
Adjustments: B=+000
X=+00 Y1=+00 Y2=+00
-
X
+
- Y+
9,50 mm
4,40 mm 2,80 mm
(Y) (Y1)
(X)