Copyright Silca 2004 91
Operating Manual - English IDEA
Fig. 117
- the machine will take the X and Y axes to a predefined
position.
-
the operator must manually rotate the X and Y photocell
disks up until the cut in the disks face the photocells
card
.
Y axis photocell:
•
manually turn the Y axis disk
(fig. 118)
up
until the
display’s description changes from OFF to ON
.
• use the provided allen key to tighten the (G3) grub screw
(fig. 118).
X axis photocell:
•
manually turn the
X
axis disk
(fig. 115, page 89)
up
until
the display’s description changes from OFF to
ON.
• use the provided allen key to tighten the (G1) grub screw
(fig. 115).
8)
lower the protective shield
.
9)
press
START.
-
the machine goes on to a new position and is ready for
regulating the sensors
.
Fig. 118
Pos. Photocell.
TZX=OFF TZY=OFF
See operating manual.
[START]
Pos. Photocell.
TZX=OFF TZY=OFF
See operating manual.
[START]
Pos. Photocell.
TZX=ON TZY=ON
See operating manual.
[START]
Pos. Photocell.
TZX=OFF TZY=ON
See operating manual.
[START]
START
START
G3 G4
Y axis photocell
Y axis sensor