92 Copyright Silca 2004
IDEA Operating Manual - English
Regulating the Y axis sensor:
•
raise the protective shield
.
• use the provided allen key to loosen the (C1) grub screw;
manually rotate the (C2) rod (fig. 119) in both directions
up until the changeover point from OFF to ON is found.
•
tighten the (C1) grub screw to secure the rod
.
Regulating the X axis sensor:
•
carefully tip the machine over
.
• remove the bottom panel by unscrewing all 8 securing
screws.
• loosen the (C3) screw (fig. 120) that secures the sensor
support plate. Manually move the sensor up until the
display’s description goes from OFF to ON.
• tighten the (C3) screw to secure the plate back into
place.
•
re-position the machine back on its workbench and
lower the protective shield
.
•
press
START.
-
the ‘machine’s zero’ settings are detected by electric
contact
.
10) when the operation has been completed, the display will
show the measured quotes.
11) press ENTER to save
12) manually turn the Y axis disk to get access to the (G4)
grub screw (fig. 118).
13) manually turn the X axis disk to get access to the (G2)
grub screw (fig. 118).
ATTENTION: if the STOP key is pressed, the new settings will be
lost. If so, only the previous setting values will remain
valid.
Fig. 119
Pos. sensors.
ICX=OFF ICY=OFF
See operating manual.
[START]
Pos. sensors.
ICX=OFF ICY=OFF
See operating manual.
[START]
Pos. sensors.
ICX=ON ICY=ON
See operating manual.
[START]
Pos. sensors.
ICX=OFF ICY=ON
See operating manual.
[START]
Zero detection
in progress!
Measured quotes:
X=4444 Y=3333
Save measurements?
No=STOP Yes=ENTER
ENTER
START
START
C2
C1
Y axis sensor