Page #86 background image
EA180 Servo Drive Manual
86
Unit
-
Valid time
Immediately
Range
0, 1~16
Data size
16bit
Control mode
S
Parameter function: when PA-00=4 , this parameter is used to select the segments to be executed.
When this parameter is set to nonzero, the specified segment speed is executed immediately. For example, when the parameter is
changed to 8, then run right away at speed PA-17 of segment , when this parameter is 0, stop and waiting for next command.
Here below is description of two parameters in association with spd1, parameters in other groups follow to the same.
PA-02
Multi-speed command spd1 running speed
Initial value
100
Commu.addr.
0A02H
Unit
rpm
Valid time
Immediately
Range
-10000~10000
Data size
16bit
Control mode
S
Parameter function: first segment speed of multi preset speed.
PA-03
Multi-step speed command spd1 running time
Initial value
1.0
Commu.addr.
0A03H
Unit
s
Valid time
Immediately
Range
0~6553.5
Data size
16bit
Control mode
S
Parameter function: when selecting cyclic operation (PA-00=0, 1, 2), the running time for the first preset speed operation.
Note
This parameter is invalid when PA-00=3 or 4.
PA-04
Multi-speed command Spd2
-1000010000
I16
-100
rpm
S
0A04H
PA-05
Running time of multi-speed command Spd2
06553.5
U16
1.0
s
S
0A05H
PA-06
Multi-speed command Spd3
-1000010000
I16
0
rpm
S
0A06H
PA-07
Running time of multi-speed command Spd3
06553.5
U16
0.0
s
S
0A07H
PA-08
Multi-speed command Spd4
-1000010000
I16
0
rpm
S
0A08H
PA-09
Running time of multi-speed command Spd4
06553.5
U16
0.0
s
S
0A09H
PA-10
Multi-speed command Spd5
-1000010000
I16
0
rpm
S
0A0AH
PA-11
Running time of multi-speed command Spd5
06553.5
U16
0.0
s
S
0A0BH
PA-12
Multi-speed command Spd6
-1000010000
I16
0
rpm
S
0A0CH
PA-13
Running time of multi-speed command Spd6
06553.5
U16
0.0
s
S
0A0DH
PA-14
Multi-speed command Spd7
-1000010000
I16
0
rpm
S
0A0EH
PA-15
Running time of multi-speed command Spd7
06553.5
U16
0.0
s
S
0A0FH
PA-16
Multi-speed command Spd8
-1000010000
I16
0
rpm
S
0A10H
PA-17
Running time of multi-speed command Spd8
06553.5
U16
0.0
s
S
0A11H
PA-18
Multi-speed command Spd9
-1000010000
I16
0
rpm
S
0A12H
PA-19
Running time of multi-speed command Spd9
06553.5
U16
0.0
s
S
0A13H
PA-20
Multi-speed command Spd10
-1000010000
I16
0
rpm
S
0A14H
PA-21
Running time of multi-speed command Spd10
06553.5
U16
0.0
s
S
0A15H
PA-22
Multi-speed command Spd11
-1000010000
I16
0
rpm
S
0A16H
PA-23
Running time of multi-speed command Spd11
06553.5
U16
0.0
s
S
0A17H
PA-24
Multi-speed command Spd12
-1000010000
I16
0
rpm
S
0A18H
PA-25
Running time of multi-speed command Spd12
06553.5
U16
0.0
s
S
0A19H
PA-26
Multi-speed command Spd13
-1000010000
I16
0
rpm
S
0A1AH
PA-27
Running time of multi-speed command Spd13
06553.5
U16
0.0
s
S
0A1BH
PA-28
Multi-speed command Spd14
-1000010000
I16
0
rpm
S
0A1CH
PA-29
Running time of multi-speed command Spd14
06553.5
U16
0.0
s
S
0A1DH
PA-30
Multi-speed command Spd15
-1000010000
I16
0
rpm
S
0A1EH
PA-31
Running time of multi-speed command Spd15
06553.5
U16
0.0
s
S
0A1FH
PA-32
Multi-speed command Spd16
-1000010000
I16
0
rpm
S
0A20H
PA-33
Running time of multi-speed command Spd16
06553.5
U16
0.0
s
S
0A21H

Table of Contents

Other manuals for Sinee EA180 Series