38 MN.00356.E - 003
6.6 SURGE AND LIGHTNING PROTECTION
- Protection Method Gas dischargers: in accordance to EN 301 489
and IEC 61000-4-5 Class4
6.7 ENVIRONMENTAL CONDITIONS
- Operational temperature range -33°C ÷ +55°C
- Temperature range of degraded performances -40°C ÷ +60°C
- Environmental conditions and environmental tests ETSI EN 300 019 Class 4.1
- Class 1.2 Storage, Class 2.3 Transportation
- Operational humidity Weather proof according to IP65
environmental class.
- Thermal Resistance Thermal resistance 0.5°C/W.
- Operating voltage range -37.5 ÷ -60 Vdc
- PoE operating voltage range -38.5 ÷ -60 Vdc
- Wind resistance < 150/200 Km/h (operation/survival).