ID Status
Thisscreendisplaystheinvertersoftwareversionandthecountrytowhichtheinverterisconfigured.
I D : # # # # # # # # # #
D S P 1 / 2 : 1 . 0 2 1 0 / 1 . 0 0 3 4
C P U : 0 0 0 3 . 1 4 x x
C o u n t r y : U S A 1
l ID:TheinverterID.
l DSP 1/2:TheDSPdigitalcontrolboardfirmwareversion
l CPU:Thecommunicationboardfirmwareversion
l Country:thecurrentcountrysetting
Server Communication Status
S e r v e r : L A N < S _ O K >
S t a t u s : < O K >
x x x x x x x x
< E R R O R M E S S A G E >
NOTE
If the connection method is CDMA (Cellular) or GSM, the server screen is replaced with the Cellular
or GSM status screens (see Cellular Status on the next page and GSM Status on the next page).
l Server:ThemethodofconnectiontotheSolarEdgemonitoringportal.
l S_OK:TheconnectiontotheSolarEdgemonitoringportalissuccessful(shouldappearonlyifthe
inverterisconnectedtotheserver).
l Status:DisplaysOKiftheinverterestablishedsuccessfulconnectionandcommunicationwiththe
specifiedserverport/device(LAN,RS485orZigBeemodule).
l xxxxxxxx:Eight-bitEthernetcommunicationconnectionstatus:Astringof1sand0sisdisplayed.1
indicatesOK,0indicatesanerror.Foralistofthepossibleerrorsandhowtotroubleshootthem,refer
toCommunicationTroubleshootingonpage79.
l Error message,accordingtofailure.RefertoErrorsandTroubleshootingonpage1.
IP Status
ThisscreendescribestheEthernetconfiguration:IP,Mask,GatewayandMACaddress(MediaAccess
Control)oftheInverter.
I P 1 9 2 . 1 6 8 . 2 . 1 1 9
M S K 2 5 5 . 2 5 5 . 2 5 5 . 0
G W 1 9 2 . 1 6 8 . 2 . 1
M A C 0 - 2 7 - 0 2 - 0 0 - 3 9 - 3 6
ZigBee Status
ThisscreendescribestheZigBeeconfiguration:
P A N : X X X X X
C H : X X / X X X X R S S I : < L >
M I D : X X X X X X
Chapter 7: User Interface
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
51