Connecting to the Battery
Tosimplifytheconnectionprocessitisadvisedtoconnectthebatterytotheinverterbeforemounting
thebatteryaccordingtothemanufacturerinstructions.
Followtheseguidelines:
l Foreasyaccesstobatteryconnectors,itisrecommendedtoconnectthecablestothebatteryand
tosetallthebatteryDIPswitchestotheircorrectpositionswhilethebatteryisstillontheground.
Thefollowingprocedureisrecommended:
a. Connectallthewirestothebatteryconnectionpanel
b. Mountthebattery
c. Assembletheconduitbetweenthebatteryandtheinverter
d. ConnecttotheStorEdgeConnectionUnit
l MeasurethenecessarylengthbetweentheStorEdgeConnectionUnitandthebatteryforallcables.
Themaximumdistancebetweenthebatteryandtheinverteris35ft/10m,whenusing16AWGfor
batterythermalpowerand24AWGforbatterycontrol.
l Tieandwrapthecablestoavoidpullingthemoutduringmounting.
l Besuretoadheretoallsafetycautionsandinformationinthebatterydocumentation.
l ThebatteryconnectstotheDCsideoftheinverter.SincetheinverterDCconnectionsareonitsleft
side,itisrecommendedtopositionthebatterytotheleftoftheinvertertosimplifywiring.
NOTE
Per NEC requirements, if the battery is more than 5ft/ 1.5m away from the inverter, an additional
external DC switch ia required adjacent to the battery.
Preparecablesandconnectasdescribedinthefollowingtable(seeFigure19):
Recommended cable type
(min-max AWG)
StorEdge
Connection
Unit
connection
Tesla battery
connection
Connection method
DC
DC cable 10AWG (10-24 AWG),
600V insulated.
BAT DC +
terminal block
DC+
o
Insert a flat blade screwdriver into
the square opening at the top of the
terminal block and press to open
clamp mechanism.
o
Insert the wire into the round
opening and release the
screwdriver to spring back and
clamp the wire.
BAT DC-
terminal block
DC-
12V thermal power input
2-wire shielded twisted pair cable
16AWG (12-28AWG), 600V
insulated
Battery
Thermal V-
(black)
THERMAL -
Push the lever to open the connection,
insert the wire and release the lever
when the wire is clamped.
Battery
Thermal V+
(red)
THERMAL +
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
30
Connecting to the Battery

Table of Contents

Other manuals for SolarEdge StorEdge SE7600A-USS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SolarEdge StorEdge SE7600A-USS and is the answer not in the manual?

SolarEdge StorEdge SE7600A-USS Specifications

General IconGeneral
BrandSolarEdge
ModelStorEdge SE7600A-USS
CategoryInverter
LanguageEnglish

Related product manuals