EasyManua.ls Logo

SolarEdge StorEdge SE7600A-USS

SolarEdge StorEdge SE7600A-USS
95 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8.
SelectBattery Infoandcheckthebatteryinformation:
S N : < s e r i a l # >
M o d e l : < X X X X X X >
R a t e d P W R [ k W H ] : N / A
F W V e r . < X X X X X >
To verify the connection:
1.
PresstheinverterexternalLCDlightbuttontodisplaythestatusscreensoneaftertheother:
a. ChecktheRS485communicationstatus:
w w w w w w w w D e v P r o t # #
R S 4 8 5 - 1 < M L T > < 0 2 > < 0 2 >
l ThenumberunderProt(protocol)shoulddisplaythenumberofconfigureddevices.
l Thenumberunder##shoulddisplaythenumberofcommunicatingdevices.
Theabovescreenshowsanexampleof2devicesonthesamebus(e.g.meterandbattery).If
RGMispre-installed,andabatteryandanexternalmeterarealsoinstalled,thescreenshould
show<3><3>.
IfthenumberofdevicesunderProtdoesnotmatchthenumberunder##,referto
Troubleshootingonpage79
b. Checkthemeter(s):Inthemeter(s)statusscreencheckthatthestatusisOK.Thefollowingisan
exampleofthestatusofanExport(orExport+Import)meter:
E x p o r t M e t e r
S t a t u s : < O K >
< E r r o r M e s s a g e >
T o t a l [ W h ] : X X X X X X X
IfComm. Errorappears,refertoTroubleshootingonpage79.
c. Checkthebatteryinformation:identification,chargingstatusandpower,andtheoperating
mode.
B S N : X X X X X X X X X I D : 2 4
S O E : 8 9 % W W W W W P W R : 0 W
T o t a l : 0 W h
S t a t e : I d l e
IfComm. Errorappears,refertoTroubleshootingonpage79.
SolarEdge-StorEdge Installation Guide MAN-01-00262-1.0
64
Configuring the RS485 Bus for Battery and Meter Connection

Table of Contents

Other manuals for SolarEdge StorEdge SE7600A-USS

Related product manuals