124
Electrical Connection
Wiring procedures
Step 1: Prepare a waterproof connector with RJ45, a RJ45 terminal and a communication
cable. An additional RJ45 terminal is not needed in meter connection.
Disassemble the waterproof connector and the RJ45 terminal inside the
connector.
»
For CT connection, strip 15 mm insulation jacket off the cable, crimp
terminal B with the cable. Thread the unstripped end of the cable through
the waterproof connector. Strip 15 mm insulation jacket off and crimp the
end with terminal A in accordance with the pin definition of CT.
»
For meter connection, strip the cable with the requirement of the Meter
Quick Installation Guide. Thread the unstripped end through the waterproof
connector. Strip 15 mm insulation jacket off and crimp the end with terminal
A in accordance with the pin definition of meter.
B
crimping tool
for RJ45
B
Figure 7-58 CT connection diagram
A
1
2
crimping tool
for RJ45
B
Figure 7-59 CT connection diagram