152
Operation on LCD
9.2 System ON/OFF
Setting path: Menu > System ON/OFF
Setting System ON/OFF
ON means the inverter is turned on, and it is the default status.
OFF means the inverter is shut down, but the LCD screen is still on.
Default: OFF
===Syetem ON/OFF===
Switch
>OFF<
Figure 9-9 Turning on/off the system
9.3 Work Mode
Setting path: Menu > Work Mode
You can select a specific work mode to decide the working principle of the inverter in this
interface.
Setting Work Mode
After entering the Work Mode interface, you can select Self Use, Feed-in Priority, Backup
Mode, Manual, Peak Shaving, TOU Mode as follows.
»
Selecting Self Use
Self Use is the default work mode. Select a work mode and press Enter to
confirm the work mode if another mode is to be selected. Select Feed-in Priority,
Backup Mode and Peak Shaving with the same logic as Self Use.
===Work Mode===
Work Mode:
> Self Use <
Press to Save.
Figure 9-10 Selecting a work mode
»
Selecting Manual
Manual is for after-sale team for maintaining devices.
Select Manual and enter the Manual interface. Forced Discharge, Forced Charge
and Stop Chrg&Dischrg can be set in this interface.
===Work Mode===
Work Mode:
> Manual <
Press to Save.
===Work Mode===
Manual:
> Forced Discharge <