3 Transportation and Storage
If the devices of X3-IES system is not put into use immediately, the transportation and
storage requirements needs to be met:
Transportation
• Observe the caution signs on the packaging of the devices before transportation.
• Pay attention to the weight of the devices. Be cautious to avoid injury when
carrying the devices. Two installers are recommended.
• Wear protective gloves when carrying the equipment by hand to prevent injuries.
• Lifting up the devices in accordance with the handling signs on the cartons.
Storage
• The inverter must be stored indoors.
• Do not remove the original packaging material and check the outer packaging
material regularly.
• The storage temperature of the inverter should be between -40
℃
and +65
℃
.
The humidity of the inverter should be between 5% and 65%.
• The required storage temperature of T-BAT-SYS: the service life may be up to 6
months in case the temperature is between -30°C and +50°C, or it may be up
to 12 months in case the temperature is between -20°C and +30°C. The relative
humidity should be between 5% and 95%. Stack the inverter and T-BAT-SYS in
accordance with the caution signs on cartons of the devices to prevent their
falling down and device damage. Do not place it upside down.
• If the T-BAT-SYS have been stored for more than 1 year, it must be checked and
tested by professionals before use.