Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
88
l) Service landing: check and set the parking landing and NW-SW function floor.
m) IC card setting: set the parameter of elevator number and service floor when IC card function
activated.
n) Time slot service floor: set the time slot allowable for each floor service.
o) Parameter summary: check and set all F parameter in the menu.
p) Control parameter service: able to reset the elevator control parameter from F0-F199. In order
to avoid unnecessary loss caused by mishandling, correct authentication code should be input
before conducting reset.
q) Drive parameter reset: able to rest the elevator drive parameter from F200-F255. in order to
avoid unnecessary loss caused by mishandling, correct authentication code should be input before
conducting reset.
r) Parameter copy: able to download the parameter set in the main broad and save in the operator.
And also able to upload the data from operator to elevator main board.
Please note: when conducting uploading or downloading, in order to avoid the unnecessary loss
caused by mishandling, correct authentication code should be input before conducting upload or
download.
adjustment operation
a) Asynchronous motor study: asynchronous motor need self-study to conduct the motor
parameter study operation.
b) hoist way self-study: let control system to conduct an study about the elevator reference
position at each floor and put those data into record.
c) Terminal landing car call: able to give the car call command about the up/down terminal
landing of elevator.
d) Test running: set the elevator auto running frequency and time interval
e) Door operation: set function of the elevator door open allowed.
f) Weighing adjustment: weighing device self-study and monitoring weighing status
reset command
The handheld operator can reset all the parameter of elevator, including fault code and elevator
running frequency. In order to avoid unnecessary loss caused by mishandling, correct
authentication code is require to be input before conducting reset.
value-added function:
Use handheld device to set the main board time , floor offset, main landing configuration,
firefighting mode and etc.
re-login
Use handheld operator to input login password to re-login main board
password modification
Able to modify the operators main board login password, use the present level password to
change the lower level password and the present level password.
5.2.2 Handheld operator connection method
Handheld operator and the integrated unit is connected with standard RS232. the connection port
at the upper part of operator is USB plug, the part of the integrated device connected to 7-segment
code operator is D-type 9-hole plug. The connection line is SM-08E/USB