Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
35
instruction registration independently, blocking instruction and outside instruction registration.
Meanwhile, user can also choose not to block.
55 External board search function
Use operator to check whether the external board at each floor work properly or not.
56 evaluations on CAN communication interference
Use the operator to check the communication quality of CAN
57 Evaluation on encoder interference
Use operator to check the interference of encoder signal.
58 car adjustment
Revolutionary elevator adjustment method is provided. Working staffs can adjust the elevator
directly inside the car, monitor the elevator running condition so as to make the adjustment of
elevator leveling, comfort and other function more user-friendly.
3.2.2 Optional function description
1. door pre-opening
The option enable leveling elevator to open door immediately upon arrival at the pre door-opening
zone. In this way the elevator operation is more efficient
2. door-opening and releveling
Due to the stretch of wire ropes in case of high-rise buildings, the parking car may move up and
down while passengers leave and board the car, which may lead to mal-levelling. Once this
situation is detected by the system, the control will make the car relevel at a slow speed with the
door open.
3.Fireman Service
The fireman switch is set on in case of fire, the elevator will immediately clear out all instruction
& call and return to firefighting base station. Then system switches to fireman service mode.
4 The auxiliary car operating Panel
The auxiliary car operating panel is available for installation when the main car operating panel is
installed. Passengers can use it to register instruction and operate the doors.
5 operating panel for the rear door
Rear door operating panel is recommended when elevator has both front and rear door. Passenger
can use the rear door operating panel to register instruction and operate the doors.
6 operating panel for the disable
Operating panel for the disabled is available for the disabled to operate the elevators.
7 group control operation
Use group control controller to coordinate landing calls of elevators in the bank. In this way the
running efficiency of elevator can be improved. And function such as peak service and distribution
waiting state are provided. The group control system can control up to 8 units
8 communities (building) monitoring
Control system link to the PCs in monitoring room through CAN communication line. Working