Instruction Manual
for
AS380 Series Elevator Integrated Drive Controller
129
situations including floor height, car call and hall call situation, elevator transcending
situation and reverse direction situation to dispatch hall call to the elevator which can
respond most quickly. Group control system can increase the efficiency of the elevator.
2 Smart ComII group control system can control up to 8 elevators at the same time; the max
floor number of each elevator is 48.
3 Group control board use CAN BUS serial communication method to communicate with
elevator control board, which assure the credible and hi-speed data transfer.
4 Group control system has back up protection function. If group control system has any
problem, it will cutoff the power supply. The elevators in the group control system can run
normally in single mode. When the group control system recover to normal, all the elevators
in system will transfer to group control mode automatically.
5 Group control system can cutoff the fault elevator. If the system find the elevator which has
received the hall call does not respond such as door-closing, the system will cutoff this
fault elevator and re-dispatch the hall call to assure the users not to wait a long time.
6 If elevator control board runs normally, the hall call is send to group control board from
elevator control board. The group control system then send call registration signal to call
controller through elevator control board to light the call button. If elevator control board is
power off, the group control system will communicate with call controller directly to assure
call controller still have effect in the system.
7 There are LEDs on the group control board; users can monitor the communication status
between group control board and elevator control board through these LEDs. Input terminals
in the group control board also have the corresponding LEDs to indicate the ON/OFF
situation.
6.6.3Main Functions
1 Homing function: automatically homing function activation is required with related
parameter setting. In group control system, if there is no elevator at home base and the
elevator which can back to home immediately has no hall call and car call register, then the
elevator will homing at once and standby with door closed. In this way can improve the home
base carrying capacity. Homing function has two mode: in standard mode, only one elevator
will return to home base automatically without time delay, in the mode of designating the
number of elevator automatically homing, the number of elevator automatically homing is set
up to four unit. Meanwhile, the homing time delay can also be set. In this mode, it is required
to use the second setting software to set the homing elevator quantity and time delay, apart
from using standard setting software for homing function activation.
2 Dispersion standby function: dispersion standby function activation is required with related
parameter setting, it also has two modes. When all elevators in the system maintain standby
status for one minute, group control system activate the dispersion standby function: a. if
there is no elevator at home base and the floor below home base, system will send an elevator
which can reach home base most easily to home base and standby with door closed. b. If
there are more than two elevators running normally in the group control system and there is
no elevator above central floor, the system will send an elevator which can reach home base
most easily to the up standby floor with door closed. In the mode of designating the floor for
elevator to standby, if all elevator maintain standby status for a certain period of time ( the
time set by parameter ) and the floor designated for elevator to standby ( max set to four)
has no elevator , the group control system will dispatch the easiest-reach elevator to the floor
designated for elevator to standby with door closed. In this mode, it is required to use the
second setting software to set the floors designated for standby and time delay for dispersion
standby, apart from using standard setting software for dispersion standby function
activation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STEP AS380-4T07P5 and is the answer not in the manual?

STEP AS380-4T07P5 Specifications

General IconGeneral
BrandSTEP
ModelAS380-4T07P5
CategoryController
LanguageEnglish

Related product manuals