127
DEFRNLIT           EN
0478 131 9965 A - EN
Perimeter wire with external docking 
station:
Route the perimeter wire (1) in the area (2) 
under the floor plate. To do this, guide the 
wire into the wire outlets (3, 4) – loosen the 
pegs if necessary.
Insert the perimeter wire (1) into the cable 
guides in the floor plate and guide it 
through the socket (2).
Connecting the perimeter wire:
Shorten the left wire end (1) and right wire 
end (2) to the same length. Length from 
the wire outlet to the wire end: 40 cm
Strip the left wire end (1) to the specified 
length X using a suitable tool and twist the 
wire strands.
X = 10-12 mm
Twist the free wire ends (1) together as 
illustrated.
● Open the panel and hold. (Ö 9.2)
Note:
Make sure that the contacts are 
clean (not corroded, dirty, etc).