EN-39
Electromagnetic Compatibility
Like other electrical medical equipment, the 1488 HD Camera requires special
precautions to ensure electromagnetic compatibility with other electrical
medical devices. To ensure electromagnetic compatibility (EMC), the 1488 HD
Camera must be installed and operated according to the EMC information
provided in this manual.
Note: The 1488 HD Camera has been designed and tested to comply with
IEC60601-1-2 requirements for EMC with other devices.
Do not use cables or accessories other than those provided
with the 1488 HD Camera, as this may result in increased
electromagnetic emissions or decreased immunity to such
emissions.
If the 1488 HD Camera is used adjacent to or stacked with other
equipment, observe and verify normal operation of the 1488
HD Camera in the conguration in which it will be used prior
to using it in a surgical procedure. Consult the tables below for
guidance in placing the 1488 HD Camera.
Equipment which employs RF communications may aect the
normal function of the 1488 HD Camera.
Guidance and Manufacturers Declaration: Electromagnetic Emissions
1488 HD Camera is intended for use in the electromagnetic environment specied below. The
customer or the user of 1488 HD Camera should ensure that it is used in such an environment.
Emissions test Compliance Electromagnetic Environment -
guidance
RF emissions CISPR 11 Group 1 1488 HD Camera uses RF energy only
for its internal function; therefore, its
RF emissions are very low and are not
likely to cause any interference in nearby
electronic equipment.
RF emissions CISPR 11 Class B The 1488 HD Camera is suitable for
use in all establishments other than
domestic establishments and those
directly connected to the public low-
voltage power supply network that
supplies buildings used for domestic
purposes, provided the following warning
is heeded:
Warning: This system is intended
for use by health care professionals
only. This system may cause radio
interference or may disrupt the operation
of nearby equipment. It may be
necessary to take mitigation measures,
such as reorienting or relocating the
system or shielding the location.
Harmonic emissions
IEC61000-3-2
Class A
Voltage Fluctuations/ icker
emissions IEC61000-3-3
Complies

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Stryker 1488 and is the answer not in the manual?

Stryker 1488 Specifications

General IconGeneral
Resolution1920 x 1080
Sensor TypeCMOS
White BalanceAutomatic/Manual
OutputHDMI, DVI, HD-SDI
Camera Head TechnologyThree-chip