SummaCut User’s Manual
General Information 1-7
1.2.7 CERTIFICATIONS
CE-Certification for electrical light industrial environment.
FCC Class A
Conforms to ANSI/UL Standard 60950-1
and certified to CAN/CSA Standard C22.2 No 60950-1
1.2.8 ENVIRONMENTAL
(Cutter without media)
Operating Temperature
15 to 35° C 59 to 95° F
Storage temperature
-30 to 70° C -22 to 158° F
Relative humidity
35 -75 %, non condensing 35 -75 %, non condensing
TABLE 1-7:
SUMMACUT ENVIRONMENTAL SPECIFICATIONS
IMPORTANT HINT
The use of dimensionally stable media is an essential pre-requisite to
obtaining high cut quality. Additionally, media expansion or contraction
may occur as a result of temperature variations.
To improve the dimensional stability of media, let it stabilise to the current
environmental conditions before usage for a minimum period of 24 hours.
1.2.9 ELECTRICAL
The power entry module detects the line voltage and switches automatically between
110V and 230V.
Main Supply: 48-62 Hz, single phase.
Nominal line Min./Max. line Fuse
110 V AC 88 - 132 V AC
T2.0A, 250V Schurter SPT
or equivalent.
230 V AC 176 - 264 V AC
T2.0A, 250V Schurter SPT
or equivalent.
TABLE 1-8:
SUMMACUT ELECTRICAL SPECIFICATIONS