EasyManua.ls Logo

Summa SummaCut D160SE - Opticut; Overcut; Panelling

Summa SummaCut D160SE
75 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SummaCut User’ s Manual
Operation 2-12
2.3.5 PANELLING
Panelling can sort data and cut out in panels. This is useful for flex cut and media
which is difficult to track. The different panelling parameters can be accessed by
pressing the
or jogging key. Press the or jogging key to change
them.
1. OFF
This enables or disables panelling. Press the
or jogging key to enable or
disable and press the
key to confirm.
2. SIZE: 100
This parameter determines the length of the panel. Press the
or jogging key to
change the value and press the
key to confirm.
3. recut: 1
This parameter determines how many times each panel will be cut. Press the
or
jogging key to change the value and press the key to confirm.
4. SORTING:ON
This parameter determines whether the vectors will be sorted and re-orientated or not.
Press the
or jogging key to change the value and press the key to
confirm.
On the LCD, the active setting is marked with an “*”.
2.3.6 OVERCUT
The OVERCUT submenu enables you to generate an overcut in order to facilitate
weeding the cut. Press the
or jogging key to change the value.
The default overcut is set to 1.
The overcut setting can be disabled (=0) or set to any value between 0(=off) and 10.
One unit is about 0.1 mm or 0.004 ".
On the LCD, the active value is marked with an “*”.
2.3.7 OPTICUT
The OPTICUT submenu enables you to generate an enhanced overcut in order to
facilitate weeding the cut. This feature however does leave little scratch on your design
and may not be appropriate for some media.
Press the
or jogging key to change the value.
The default value is set to OFF.
On the LCD, the active value is marked with an “*”.