SummaCut User’ s Manual
Operation 2-6
2.2.6 POUNCING PRESSURE
The POUNCING PRESSURE submenu is used to set or modify the pouncing pressure
of the pouncing tool.
The default pouncing pressure value is 120 grams.
After pressing the
key, press the or jogging key until the desired
pressure is displayed on the LCD and press
to confirm.
The pouncing pressure can be set between 0 and 250 grams.
The pouncing pressure value is set in 5 gram increments.
On the LCD, the active pouncing pressure value is marked with an “*”.
Pouncing pressure set-up is explained in detail in section 1.8.1.
2.2.7 POUNCING GAP
The pouncing gap submenu is used to set or modify the distance between the pounced
wholes. This routine applies to the pouncer only.
The default pouncing gap value is 1 mm.
After pressing the
key, press the or jogging key until the desired
pouncing gap is displayed on the LCD and press
to confirm.
The value can be set between 1 mm and 50 mm.
On the LCD, the active pouncing gap value is marked with an “*”.