Appendix A Sun StorEdge 3510 and 3511 FC Array Specifications A-3
A.2 Sun StorEdge 3510 and 3511 FC Array
Highlights
The following topics briefly describe specific hardware and firmware features.
Feature Description
General • Up to 12 hot-pluggable drives in a 2U (3.45 in. / 8.76 cm high) chassis
• Autosensing AC or DC power supplies
• Dual-host access in certain configurations
Density • Up to 1752 GB in a RAID array (with 146 GB drives)
• Up to 3 TB in a RAID array (with 250 GB drives)
• 21 in. chassis depth
• Sun StorEdge 3510 RAID supports up to eight expansion units
• Sun StorEdge 3511 RAID supports up to five expansion units
Reliability • Redundant hot-swappable FRUs
• Single or redundant active/active hot-swappable RAID controllers
• N+1 hot-swappable power and cooling
• NEBS Level 3 and HALT test certified; designed to meet 99.999% reliability
RAID System
Storage Resource
Management
• Web-based 10/100BASE-T Ethernet support
• Serial port out-of-band support with modem control
• RAID Levels 0, 1, 1+0, 3, 3+0, 5, and 5+0
• Up to 1024 LUNs
• SNMP traps and MIB in firmware
• 1-GB cache memory standard
• Sun StorEdge 3510 FC arrays include four channels that are user-configurable as drive
or host channels and two channels are dedicated drive channels
• Sun StorEdge 3511 FC arrays include two channels that are user-configurable as drive
or host channels, two channels that are dedicated drive channels and two channels
that are dedicated host channels
• Support for Sun StorEdge Configuration Service and Diagnostic Reporter
management software