Chapter 4 Servicing Motherboard Components 4-49
13. After a successful flash, remove the AC power.
See Section 2.4, “Powering Off the Server” on page 2-3.
14. Remove the jumper.
15. Remove the flash drive from the USB port.
16. Replace PCI cards from Riser 1.
See Section 4.6.3, “Installing a PCIe Card” on page 4-26.
17. Reinstall the top cover.
See Section 6.1, “Installing the Top Cover” on page 6-2.
18. Slide the server into the rack.
See Section 6.3, “Returning the Server to the Normal Rack Position” on page 6-4.
19. Reconnect the power cord (or cords) to the power supply (or supplies).
Verify that the AC Present LED is lit.
See Section 6.4, “Powering On the Server” on page 6-5.
20. Power on the server.
See Section 6.4, “Powering On the Server” on page 6-5.
21. Start the BIOS.
22. Confirm that the SP is listed in the BIOS settings under Server/AST2000 LAN
Configuration.
23. Exit the BIOS and start the operating system.