OPERATION & MAINTENANCE MANUAL SWE18UF
32
with clean water, and consult a doctor immediately for
medical attention.
1.4.12 Safety Operation for High-Pressure Hoses
If oil or fuel leaks from high-pressure hoses, it may cause fire or defective operation, which may lead to
serious injury. If any loose bolts are found, stop work and tighten to the specified torque. If any damaged
hoses are found, stop operations immediately and contact your SUNWARD distributor.
Damaged hose, deformed mouthpiece, damaged O-ring.
Frayed or cut covering or exposed reinforcement wire layer.
Covering swollen in places.
Twisted or crushed movable portion of hose.
Foreign material embedded in covering.
1.4.13 Accumulator
Accumulator is charged with pressurized nitrogen. When
handling accumulator, careless operation may lead to
explosion and cause serious injury or damage. Always
follow the following instructions.
Do not disassemble accumulator.
Do not keep accumulator close to fire or expose it under
flame.
Do not drill holes, weld or heat up on accumulator.
Do not hit or roll accumulator to avoid any shock on it.
When handling accumulator, bleed the air.
Please contact SUNWARD dealer to get assistance with
this work.
1.4.14 Preventing Battery Explosion
Do not allow any lightened matches or other flame to
approach battery upper side. Failure to do so may cause
explosion.
Use voltmeter or hydrometer to measure electricity; do
not measure the electricity of battery by short circuiting.
Do not use or charge the battery if the battery
electrolyte level is below specific volume. Failure to do
so will cause battery explosion.
Do not charge frozen battery, failure to do so may cause