OPERATION & MAINTENANCE MANUAL SWE18UF
95
or adhesive tape to avoid the entering of dust.
11) Clean the interior of the casing ⑧.
12) Use dry compress air whose pressure is lower than 686kPa
to clean air filter element ⑦, first, blow along the flute of
interior of the filter element, than blow from outside, finally
blow from the interior.
13) Light a lamp in the filter element, check the filter element ⑦, replace it immediately whether any hole
or spot is detected.
14) Remove the cloth or adhesive tape of step 10.
15) Install filter element ⑦.
16) Install dust collection cup ⑥, keep the “TOP” mark up,
then lock the lock catch ⑤.
Connection pipeline between air filter and engine
Check seal…every day
Replace…When pipeline has crack and air leakage
5.2.7 Cooling System
1. Check cooling water level
2. Check and adjust fan belt
tension
4. Clean radiator and
hydraulic oil cooler
core
Decrease pressure of compressed air,
keep other people away from operation
site, beware of flying debris and wear
personal safety device.
FIG.100
FIG.98
Never start engine when the
hydraulic oil tank is empty.
If bad seal or crack occurs on
connection pipeline, dirty air
will enter and damage engine.
FIG.100
FIG.98
Never start engine when the
hydraulic oil tank is empty.